Conventional fire alarm control panel 4-16 zones
Conventional fire alarm control panel 4-16 zones
Series : fire alarm control panel
Spec : 4,8,16 zones panel 200 to 240VAC 50/60 Hz
Material : Metal
Color : Red
Brand : ZOANCO
Model : ZC-CP1000
Size : 353mm(L)×282mm(H)×101mm(W)
Original : 0.00
Detail

Introductions


The fire alarm control panels (4 Zones, 8 Zones, and 16 Zones) provide all of the

sophisticated features required of a leading edge conventional fire alarm system along

with the simple operation and efficient installation methods demanded by both

installers and building users.

The panel can be flush or surface mounted and the generously sized metal back box

allows ample space for rear or top cable entries.

Acomprehensive range of auxiliary devices is available to operate with the fire

control panels including optical, ionization, photoelectric, and heat detectors.

Each of the system components has been specifically designed to operate as part of

the system. This provides assurance that the control panel, smoke detectors,

interface devices and the ancillary components are all fully compatible with one

another and that the full range of system functionality is supported by each device.

1.1 Product features

The panels have the following key features:

 4, 8, or 16 conventional input zones.

 2 notification appliance circuits (NAC, Sounder) with built-in

synchronization forANSI 3.41and Gentex.

 The panel comes with a 3 amp power supply.

 Dedicated alarm and fault relays.

 1 RS485 can be able to connect repeaters.

 Enclosure supports two 12V, 7Ah backup batteries.

1.2 Electrical specifications

PrimaryAC 200 to 240VAC 50/60 Hz

Standby current: 50mA@220VAC,Alarm current: 85mA@220VAC

Power supply rating 3Amps @ 24VDC

Maximum Battery Charging Current 0.98 Amps @ 26VDC

Initiating Device Circuits 4 Zones Alarm Zone 1, 2, 3, & 4

Initiating Device Circuits 8 Zones Alarm Zone 1, 2, 3, 4, 5, 6, 7, & 8

Initiating Device Circuits 16 Zones Alarm Zone 1, 2, 3, 4, 5, 6, 7, 8,9,10,11,12,13,14,15, &16

Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated

Short Circuit Initiating Current (per zone) 35mAMaximum

Maximum Initiating Resistance (per zone) 10 ohms

Initiating End-of-Line Resistor 4K7 ohms, 1/2W 5%

Standby Detector Current (per zone) 4mAmaximum

Maximum Detector Count (per zone) 30 detectors

Initiating Cabling Type 18AWG Twisted Shielded pair (14 – 18 AWG)

Detector Base Impedance 430 ohms

NotificationAppliance Circuits(Sounder) 2 NACs, SpecialApplication

Maximum NAC Current Rating 1Amp maximum per circuit

NAC End-of-line Resistor 10K ohms 1/2W 5%

FAULTRelay rating 2A& 30VAC, resistive

Alarm(Auxiliary ) Relay rating 2A& 30VAC, resistive

Enclosure Dimensions 353mm(L)×282mm(H)×101mm(W)

Net Weight 3.1kg (Without batteries)